Implementasi Kontrol Proportional - Integral Pada Pengaturan Suhu Steamer Baglog

Implementation of Proportional - Integral Control in Baglog Steamer Temperature Control

NADIRA AISYAH IBRAHIM

Sterilization is oyster mushroom cultivation processes. Sterilization is used to kill nuisance microorganisms that can inhibit mushrooms growth. The strerilization process is 8 hours at temperature of 70oC – 95oC. This process of frequent breakdowns caused by the unstable of temperature sterilizations space and controlled manually. Based on these problems, the right solution is to use a steamer that can be controlled automatically using the PI control method. In its manufacture, Arduino Mega 2560 is used as the main microcontroller with analog input expansion for PT100 temperature sensor readings and will be displayed on the LCD, DC motor as actuator and RTC as system stopper. The results of the PI control parameters obtained the value of Kp = 25.2, and Ki = 0.302. By using the Kp and Ki values that have been set, the sterilization process can work faster to 6 hours and the system can work well and maintain temperature stability according to the set point.