Eksperimental Penyempurnaan Tumpuan Jenis Base Isolation untuk Mereduksi Pengaruh Gempa pada Model Portal Baja
The Improvement's Experimental of Base Isolation to Reduce Earthquake Effect in Steel Portal Model
One of the most visible impact of an earthquake is damage to building structures. The purpose of this thesis is to design base isolation with varians of roller that resistant to lateral earthquake forces and find out the cost estimate of base isolation modelling workmanship. The required data are five-story, ten-story, fifteen-story steel portal design, base isolation design, El Centro 1940’s earthquake time history and unit price list. The analysis process is using STAAD Pro V8i and Microsoft Excel. Based on the STAAD Pro V8i analysis results, obtained a reduced response on ten-story portal roof with two roller’s base isolation which has an average acceleration of 22%, causing a maximum acceleration of 19%, a maximum displacement of 27% and on five-story portal roof with three roller’s base isolation which has an average acceleration of 27%, causing a maximum acceleration of 31%, a maximum displacement of 64%. While from the shaking table testing analysis results, obtained a reduced response in conditions of moderate damage on ten-story portal roof with two roller’s base isolation which has an average acceleration of 20%, causing a maximum acceleration of 22% and on five-story portal roof with three roller’s base isolation which has an average acceleration of 38%, causing a maximum acceleration of 35%, and the total cost estimate of base isolation modelling specimen workmanship is about 270.000 rupiahs.