Analisis Kecepatan Angin Dan Sudut Serang terhadap Tegangan Kerja Konstruksi Rotor Turbin Angin Sumbu Horizontal Baling-baling Pipa Terbelah Spiral Berdaya 500 Watt

An Analysis of Wind Velocity and Angle of Attack on Working Stress Rotor Construction of Wind Turbine Horizontal Axis Propeller Pipe Split Spirally 500 Watts Powered

MIFTAHUL HUDA

The current problem is designing wind turbines from materials that are easily found on the market, one of which is pipes. The real function of a pipe is to drain a fluid. Thus it is necessary to analyze the work stress that occurs in construction, so that the wind turbine pipe propeller can be applied in the community. The purpose of this study is to determine the effect of wind speed and blade angle of attack on the working voltage. Thus the importance of work stress analysis as a basis for understanding appropriate technology to be applied in society. In the simulation test using the Software SolidWorks Flow Simulation then the results of the test are exported to the Static Simulation to find out the voltage value, the simulation test is carried out loading on the PVC pipe blades with wind speeds of 5 m / s, 6 m / s, and 7 m / s and blade angle of attack -12.8°, 0° and 12.8°. The results of the maximum stress value in the wind turbine simulation test with the addition of the web obtained at wind speed of 7 m / s and the attack angle 12,8°, which is 7,752E+06 N/m² or 7752 MPa, while the wind turbine simulation testing without additional web obtained at a wind speed of 7 m / s and an angle of attack of 12,8° which is 2.893E + 06 N/m² or 2893 MPa.