Perencanaan Perawatan dan Perbaikan Primary Air Fan Double Inlet Type Centrifugal Kapasitas 133 m³/s Periode 2019 s.d. 2021

The Planning of Maintenance and Repair on Primary Air Fan Double Inlet type Centrifugal with the Capacity of 133 m3/s Period 2019 - 2021

JERRY KURNIANSYAH RIFALDI

In the steam power plant, a primary air fan is used to drain the air as a drying coal and to carry of brick powder from pulverizer through to the furnace. The air fan flow through two channels, that are hot air ducting and cold one. The air from them channels will be mixed before flowing into the pulverizer and then intake to the furnace. The purpose of the planning of maintenance and repair is to keep condition of the primary air fan and to reduce the maintenance’s cost as low as possible. The general damage occurred in the primary air fan are pillows block bearing worn, dust seals are broken, screen is corrossed, broken lube oil filter and lube oil cooler fan are not functioning properly. The planning of maintenance and repair is using Inspection, Small Repair, Medium Repair and Overhaul method (ISMO). This planning is also calculating the estimated cost of the maintenance and the repair. The results of this planning are the maintenance and the repair schedule of the primary air fan in the period 2019 - 2021 and the estimated cost is Rp. 362.762.900,00