Perencanaan Ulang Struktur Atas Gedung Tempat Parkir RSUD Dr. Saiful Anwar Malang
The Upper Structure Redesign of Parking Area Building of RSUD Dr. Saiful Anwar Malang
The 3-storeyed parking lot building of RSUD Dr. Saiful Anwar Malang is of 1089 m2. This building has 35 m long and 11 m wide. The roof structure uses curved roof frame and super structure uses steel construction, profile column WF 300.150.6,5.9, profile beam WF 200.100.5,5.8 and WF 150.75.5.7. The purpose of this final project is to redesign the super structure and roof frame into reinforced concrate super structure and roof gable frame to get an alternative design in terms from cost estimation. Load and Resistance Factor Design (LRFD) method referring to SNI 17292015 is used for steel calculation. SNI 03-2847-2013 is for the reference of concrete structure. Autodesk Robot Sructural Analysis Professional 2015 is for the static analyses and Auto CAD 2014 is for the technical drawings. The redesign results in roof structure of 150.65.20.3,2mm lip channels profile for 300.150.6,5.9mm purlin of WF profile for gable frame; 10mm sagrod steel bar, 10mm for wind brace; concrete structure of: 125mm deep slap 10mm main steel bar and 150mm and 8mm distribution steel bar for slab; 40/40cm beam for pedestal reinforcement uses 8D16mm top steel bar, 3D16mm bottom steel bar; and strip reinforcement uses 3D16mm bottom steel bar; 2D16mm top steel bar; 10mm shear steel bar; 40/40cm colum uses 6D19mm main steel bar with Ø10-300mm shear steel bar; stairs uses D10mm–100mm main steel bar and Ø8–100mm distribution steel bar, Budgeting reviewed costs IDR. 67.764.527.