Sistem Kendali Buck-Boost Berbasis Pid Untuk Meningkatkan Kinerja Solar Cell

Buck-Boost Control System Based PID to Improve Solar Cell Performance

DIMAS RENGGA OKTAFIYAN

Solar Power Generation (PLTS) is one of the energies being developed by the Government of Indonesia at this time because as a tropical country, Indonesia has huge solar energy potential. Currently the government has issued a roadmap of solar energy utilization until 2025 is amounted to 0.87 GW or about 50MWp / year. This amount represents a considerable market potential for future solar energy development (Yandri, 2012). PLTS has a major component of solar panels that are able to convert solar energy into electrical energy. In its implementation, the electrical energy generated by solar panels is strongly influenced by the temperature and intensity of sunlight. This causes the voltage received by the solar panel to change constantly in accordance with the intensity of sunlight and the temperature received by the solar panel. Basically the solar panel is a DC power plant The working principle of this circuit is to fill the voltage in the 12 Volt / 20 A battery. The voltage range produced by the solar panel after entering the buck-boost converter is stable at 14 Volts. By implementing the PID (Proportional Integral derivative) method with the parameters Kp = 14, Ki = 1.8 and Kd = 9.5 in buckboost, the PID method is able to work in accordance with the specified setpoint. However, it causes system overshoot. Percent Overshoot (PO) generated at the initial starting of 37%

Subjek

© 2026 UPA Perpustakaan POLINEMAStatus LayananKebijakan PrivasiSyarat & Ketentuan

v2026.11.26.1 · de96334