Pengolahan Limbah Cair Penyamakan Kulit untuk Menurunkan Kadar Cr, COD, dan TSS dengan Menggunakan Elektrokoagulator Kontinyu
Processing of Tannery Liquid Waste to Reduce Cr, COD, and TSS Levels by Using Continuous Electrocoagulator
SAFRIE SYAMSUDDIN PRIMADINATA, TIMOR SANDI NANGGALA
Waste from PT Nasional Djawa Kulit industry has very high levels of Cr, COD and TSS pollutants with the resulting Cr content of 2158 mg / L, COD of 9933 mg / L, and TSS of 5117 mg / L. Quality standard values according to the Republic of Indonesia Minister of Environment Regulation Number 5 of 2014 concerning Waste Water Quality Standards for industrial activities are Cr levels of 0.6 mg / L, COD levels of 110 mg / L, and for TSS levels of 60 mg / L. The purpose of this study was to reduce and determine the efficiency of decreasing Cr, COD, and TSS levels through the electrocoagulation process using a continuous electrocoagulator and the research variables used were voltage (3 volts, 6 volts and 9 volts) and installation of electric current circuits on the electrode ( Monopolar Series, Parallel Monopolar, and Parallel Bipolar). The research was carried out on a laboratory scale continuously with a volume capacity of 40 liters. The electrodes used are aluminum (Al) as an anode and stainless steel as a cathode. Based on the research that has been carried out that the best efficiency decrease for Cr levels is 90.16%, COD levels are 89.16%, and TSS levels are 60.91% by using a variable voltage of 6 volts and electric monopolar parallel electrode circuits.