Penetuan Dosis Koagulan dan Flokulan pada saat Dredging Retention Basin terhadap Kualitas Air Limbah Buangan di Waste Water Treatment Plant PLTU Tanjung Jati B Power Services Unit 1 dan 2.

Determination of Coagulant and Flocculant Dose on Dredging Retention Basin Waste Water Treatment Plant in Tanjung Jati B Power Plant Power Services Uniit 1 and 2.

HIDAYATUL NURIL ILMIYAH, ANGELICA ELISABETH

So far, there is no provision which become the basis for the dose coagulant and flocculant to be used during dredging condition in Retention Basin, but only by maximizes the aperture of stroke injection pump and by dripping of additional polymers. The use of this dose can make the quality of waste water from WWTP in accordance with the provisions of TJB Environmental Monitoring and Measuring Program but but its use is too much and makes wasteful. This research aims to determine the best dose of coagulant and flocculants to waste water quality during the dredging process in retention basin. Dosage determination is based on the size of the test parameters which include Total Suspended Solid (TSS), pH, Turbidity, Fe, and Cr. In this study, coagulation and flocculation processes were carried out in a laboratory scale with a batch system (Jar Test) using a sample volume of 1000 mL. The coagulant used was FeCl 3 with variable doses of 3 ppm, 5 ppm, 7 ppm, 10 ppm, and 12 ppm, while the flocculant used was Nalco N9901 polymer with variable doses of 2 ppm, 4 ppm, 5 ppm, 7 ppm, and 10 ppm and Nalco N8100 polymer with a dose of 1- 4 ppm. The samples were analyzed using an analyzer, namely a spectrophotometer for TSS, Fe, and Cr analysis, pH meter to analyze pH, and a turbidimeter to analyze turbidity. The addition of the number of coagulant and flocculant doses affected TSS, and Settling Time at the time of the jar test and the application in the field. The results of this experiment indicate that five samples variable coagulant dose of FeCl3 3 ppm, polymer flocculant N9901 4 ppm, and polymer N8001 with a variable dose of 1 ppm applied during the research processes, significantly affect the percentage reduction of TSS maximally, the allocation of settling time becomes faster, and requires the least amount of chemical addition. It’s made TSS decreased by 99.39% , pH 7.36, turbidity 18.9 NTU, decreased Fe by 99.11%, purity Cr by 99.78% and settling time less than 2 minutes.

© 2026 UPA Perpustakaan POLINEMAStatus LayananKebijakan PrivasiSyarat & Ketentuan

v2026.11.19.1 · c557b04