Pengolahan Limbah H2S Di American Petroleum Interceptor II PPSDM MIGAS Cepu Dengan Adsorpsi Karbon Aktif Atau Penambahan Tawas (Al2(SO4)3)

Treatment Of H2S Waste In American Petroleum Interceptor II PPSDM MIGAS Cepu With Active Carbon Adsorption Or Addition of Alum (Al2(SO4)3)

Vivi Novida Kusumaningrum, Zakiyatul Latifah

Refinery waste treatment unit is a place used to treat wastewater that comes out of the oil and gas refinery processing process. API II is the last place to treat wastewater at PPSDM MIGAS Cepu before the water is discharged in a water body, namely the Bengawan Solo river. Data average on dissolved H2S levels in the November 2020 untill Januari 2021 is 1,2 mg/L. From the H2S waste data, it still exceeds the quality standard of 0.5 mg/L according to PERMEN LH No.19 of 2010. Therefore, H2S waste treatment is needed. In this study, which was carried out by comparing two methods, namely the activated carbon adsorption method with the addition of Al 2(SO4)3 method. The analysis carried out is a test using Iodometry (H2S content), pH test, and turbidity test. From the results of the study, it was found that the use of alum was more effective than the use of activated carbon, the results of H2S wastewater treatment using alum pH value 7; turbidity of 0.0540 NTU; and H2S levels of 0.061 mg/L. With this wastewater treatment, H2S levels in the API II PPSDM Migas Cepu can be below environmental quality standards.

© 2026 UPA Perpustakaan POLINEMAStatus LayananKebijakan PrivasiSyarat & Ketentuan