Analysis Electrical Energy Consumption of Flexible Conveyor Machines for Gallon Mineral Water Loading Processes

Muhammad Aldo Arimirza Amruddin

The flexible conveyor machine plays a vital role in gallon mineral water loading processes, where energy efficiency directly influences operational costs. This study analyzes its electrical energy consumption from no-load to maximum load, estimates monthly operating costs, and evaluates performance with a designed solar photovoltaic system. Experimental measurements under varying load conditions, tilt angles, and Variable Speed Drive (VSD) frequencies revealed that the highest consumption occurred at a 15° tilt with a 5 kg load at 50 Hz, reaching 193.52 W. Under typical operation (35 Hz, 15° angle, 5 kg load, 1 hour/day), energy use was 0.147 kWh/day or 4.41 kWh/month, with a calculated monthly cost of Rp 5,963.52 at the R-1/TR tariff effective July 2025. Solar system testing using a 4S LiFePO4 (12.8 V, 80 Ah) battery failed to start the conveyor due to insufficient starting current from voltage drop and cell imbalance, highlighting the need for battery cell equalization, gradual charging via a 100 WP monocrystalline panel, or cell replacement. Findings confirm that while grid-powered operation is relatively energy-efficient, system modifications are essential to achieve reliable off-grid performance.

© 2026 UPA Perpustakaan POLINEMAStatus LayananKebijakan PrivasiSyarat & Ketentuan