Design And Implementation Of Pv-Based Back Up Supply For Gallus Domesticus Egg Incubator

Muhammad Aouky Syafaatuullah

Various problems in the hatchery industry such as power outages which result in egg incubators not working during the egg hatching process, implementing a solar PV system that will work automatically to back up the egg incubators when the power goes out In this study there are several stages. To get the necessary data so that the results of the analysis carried out are as desired, the capacity to support the backup supply of the Gallus Domsticus egg incubator which is planned to be able to replace PLN main supply with a solar PV system and is supported by the ATS AMF. System for automatic switching in the event of a supply failure from PLN, on the calculation of a 12 hour back up using a 150Wp solar panel and a 30A solar charger controller a 100Ah battery. After 12 hours of use spends 300kWh and charging in 10 hours of drying energy produces 900Wh and data collection for 7 days when charging starts at 07.00am s/d 17.00pm the peak production of solar PV is 7.1A with an average voltage of 13.9V, the average production peak at 8.00am-15.00pm. In one day gets 536Wh and the backup system experiment is carried out at night from 18.00pm to 06.00am hours relying only on energy from a battery that does backups for 12 hours by draining the battery as much as 766Wh the difference should be calculated.